sectional cold water storage tanks
Links
-
5, according to the wire diameter thickness to adjust zinc dipping time
-
Post time: 26-10-22 - The tensile resistance of welding net to 120N, otherwise for unqualified welding net. In this respect, there is no simple way to test the tensile resistance of the welding net, only through professional tools, expert testing to test, we will not introduce in detail. The outcrop on both sides of the welding net should not exceed 2MM. The welding net diameter wire and weft wire crossing place should be welded firmly, but the edge of the welding net to weld firmly weft wire must come out some, to weld firmly, but can not come out too much, generally not more than 2 mm is qualified welding net.
- Aperture: according to customer requirements (mm)
- Galvanized wire is coated with a layer of stable zinc on the outside of the wire, and the zinc layer is used to protect the wire and make the service life of the wire longer. In the production of galvanized wire, the wire should be pickled. Pickling is to use some acid mist or acid liquid to wash away some oxides on the surface of iron, that is, rust, and some other corrosion, to achieve the purpose of cleaning iron, so that zinc will fall off when galvanized.
-
The barbed rope factory will store the blade barbed rope in a suitable place when it is stored, because it understands the product characteristics.
- One: according to the different color of the spray blade, its price is higher than that of the ordinary blade, but the cost performance of the spray blade is much higher.
-
One is the frame isolation net, guardrail net with frame, frame using material cold plate belt welded into the square tube, usually 2*3 thickness 1.2 thick, the middle for low carbon steel wire welding mesh, wire diameter can choose another welding aperture can also choose, for example, customers want good quality long service time, you can choose thick wire diameter, small welding aperture, Such mesh is not only high quality, but also long service life, customized mesh and frame after welding, surface treatment to reach the customer needs of goods.
- A. When the thickness of the plating is 3-4 mm, the zinc adhesion should be less than 460g/m, that is, the average thickness of the zinc layer is not less than 65 microns.
- (2) The construction is simple and does not need special technology;
-
If the zinc coating is good, but when the light comes out in 3% nitric acid, there is a dark shadow on the coating, and the film is brown when passivation occurs, which may be caused by foreign metal impurities such as copper or lead in the galvanized liquid. When there is a problem in the process of galvanizing, check the temperature and current density first, and then measure and adjust the content of zinc and sodium hydroxide in the bath through the analysis of the bath. Whether DPE levels are low can be determined by Hull cell test.
- 4, barbed wire protective net and culvert intersection, such as the ditch is narrow, barbed wire barbed wire protective net can be directly crossed, the ditch is wide, barbed wire barbed wire protective net is difficult to cross, can take the treatment method of bridge, channel.
-
The quality of hot-dip galvanized barbed wire is only the zinc layer attached to the surface of the wire, and with the chemical reaction, the zinc layer on the surface will gradually lose its role because of the oxidation reaction, which is more prominent in the humid environment. And because the use of rusty wire after all, it is said that the quality of hot-dip galvanized barbed wire is certainly not up to the level of stainless steel barbed wire.
- 2, galvanized wire mesh molding sheet storage ground should be flat, according to the symbolic requirements of the accumulation of regular, height should not exceed 2M, and away from heat sources, avoid exposure.
-
Electric galvanized shaft wire direct selling is in the plating tank through the current unidirectional zinc gradually plated on the metal appearance, the production speed is slow, uniform coating, thin thickness, usually only 3-15 microns, bright appearance, poor corrosion resistance, generally a few months will rust. Compared with hot dip galvanizing, the production cost of electric galvanizing is lower. The difference between cold galvanizing and hot galvanizing: the difference between cold galvanizing and hot galvanizing is that the amount of zinc is different. They can be identified from the color. The color of cold galvanizing is shiny silver white with yellow. Hot dip galvanizing shiny white.
- ③ Galvanized iron wire shall not be damaged when it is tightened.
- The structure of the hook mesh is essentially permeable to air and water, which has a strong tolerance for the natural effect and filtration effect of groundwater. The suspended matter and silt in the water can be piled up in the rock filling joint and applied in mountain protection, which is conducive to the growth of natural plants and beautify the grass spray to reach the curing effect of their own in the later period. The gradual restoration of the original ecological environment is a perfect connection between beautification and protection.
- 2. The cleaning agent used for cleaning should have no effect on the binding force of the coating and no corrosion on the matrix.
-
Galvanized wire mesh is divided into hot dip galvanized wire mesh and cold galvanized wire mesh. Galvanized steel wire net selects the high quality low carbon steel wire, iron wire factory made by precision of automation machinery welding technology processing, smooth surface, firm structure, integrity is strong, even if the local cutting of galvanized steel wire net, or local also under pressure from loose phenomenon, after molding, wire mesh galvanized corrosion resistance good, has the advantage that the general steel mesh does not have.
-
In the purchase of large rolls of galvanized wire, see the hardness of galvanized wire first, only after the hardness reaches the standard can be used. The hardness standard of large roll galvanized wire is a very important performance index and an economic test method. But for the hardness of metal materials, there is not a unified and clear definition including all test methods at home and abroad.
- Twisting the barbed wire: twisting the barbed wire in the opposite direction of the main wire. That is, it’s not twisted in one direction. This is called the twisted cord.
- The wide application of galvanized wire has brought great convenience to people’s production and life, but the production process of iron wire is not to be underestimated. In industrial production, the production process of galvanized wire should be strictly controlled to ensure the quality of galvanized wire.
- Zinc-coated wire is dipped in molten zinc with high production speed and thick but uneven coating. The thickness allowed by the market is 45 microns, the color is dark, the consumption of zinc metal, and the base metal to form infiltration layer, good corrosion resistance, hot dip galvanizing can be maintained for decades in the outdoor environment.
-
Second: positive and negative twisting rope cost-effective
-
Now most people buy barbed rope choose blade barbed rope, why is this? The blade gill net is made of hot-dip galvanized steel plate or stainless steel sheet to punch out sharp knife sheets. The high tension galvanized steel wire or blade barbed wire is made of stainless steel wire as the core wire. Because the gill net shape is not easy to contact, so it can reach excellent protection barrier effect. The primary raw materials of the product are galvanized sheet and stainless steel plate.
-
National standards on the use of wire mesh standards have certain requirements, diameter and mesh size matching use, rather than simply diameter, on the plaster layer to use the mesh should not be greater than 20×20, diameter is not easy to be less than 1mm, just choose diameter is not much meaning, choose 40×40×0.9 and choose 10×10×0.6 wire mesh, Which is better? I’m afraid it’s 10 by 10 by 0.6.
-
Take 20cm galvanized wire for acid fog experiment, check the zinc content of galvanized wire through the balance to see whether it meets the zinc layer standard required by customers, ensure that the metal wire achieves the role of rust and corrosion prevention, and meet the service life required by customers. Galvanized iron wires must be packed in good condition, bound neatly and orderly, and bound inward to prevent scratches during transportation. The inspection standard of galvanized iron wire also includes the tensile test, which is decided according to the material of the galvanized wire order ordered by the customer, and it needs to be tested by comparing the raw material list.
-
Hexagonal guardrail network custom corrosion lost the original characteristics, in the shape, color and mechanical properties will change, resulting in equipment damage, pipeline leakage, etc., specifically, it is easy to break, lose the original protection function.
- wire mesh fence sizes
- 3d welded wire fence
- 4 ft black chain link fence cost
- 2 inch welded wire mesh
- 2 inch x 2 inch wire mesh
- 72 x 100 welded wire fence
- 16 gauge galvanized wire fencing
- brc weld mesh
- plastic coated tie wire
- pvc gi wire